• Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump
  • Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump
  • Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump
  • Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump
  • Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump

Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump

Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Work Environment: Low-temperature Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Samples:
US$ 920/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GT-SKR020KBDC-M290
Certification
CE, ISO9001, CCC, CB
Power Supply
220-240V/1pH/50Hz
Housing Material
Galvanized Steel
Transport Package
Carton or Plywood
Specification
1100*460*795mm
Trademark
Guangteng or OEM
Origin
Shunde- China
HS Code
8418612090
Production Capacity
5000pieces/Year

Product Description

Important Information Of Heat Pump GT-SKR020KBDC-M290:
Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump


Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump


Technical Data: 
Model number   GT-SKR020KBDC-M290 GT-SKR030KBDC-M290 GT-SKR040KBDC-M290
Heating at A7/W35
Heating capacity (min-max) kW 6.40 (2.83~8.00 ) 8.30 (3.65~10.38) 11.6 (5.10~14.50)
Power input (min-max)  kW 1.47 (0.65~1.84 ) 1.93 (0.85~2.42) 2.75 (1.21~3.44)
COP W/W   4.34 (3.03~5.21) 4.30(3.01~5.16) 4.22(3.03~5.10)
Heating at A2/W35
Heating capacity (min-max) kW 5.80 (2.55~7.25 ) 7.11 (3.13~8.89 ) 10.43 (4.59 ~13.04 )
Power input (min-max)  kW 1.60(0.71 ~2.00) 2.06 (0.91~2.58) 2.76(1.22~3.45)
COP W/W 3.60(2.52 ~4.32)  3.45(2.48~4.30) 3.78 (2.65~4.54)
Heating at A7/W55
Heating capacity (min-max) kW 5.75 (2.53~7.19) 7.7 (3.40~9.63 )  11.08 ( 4.88~ 13.85 )
Power input (min-max)  kW 2.03 ( 0.89 ~2.54 ) 2.70 ( 1.19 ~3.38)    3.82 ( 1.68 ~ 4.78 )
COP W/W 2.83 ( 2.3 ~3.8 ) 2.85 ( 2.00~ 3.42)    2.90 ( 2.03 ~ 3.48 )
Heating at A2/W55
Heating capacity (min-max) kW 5.14 ( 2.27 ~6.43 ) 6.72 (2.96 ~ 8.40 ) 9.61 ( 4.23 ~ 12.00 )
Power input (min-max)  kW 2.06( 0.91 ~2.58 ) 2.71 ( 1.20 ~ 3.39 ) 3.74 ( 1.65 ~ 4.68 )
COP W/W 2.45 ( 2.00 ~ 3.45 ) 2.48 ( 2.00 ~ 3.60) 2.57 ( 2.20 ~ 3.70 )
Cooling at A35/W7
Cooling capacity  (min-max) kW 3.70 ( 2.22 ~ 5.92 ) 6.20 ( 3.40 ~ 8.10 )     9.30 ( 5.22 ~ 12.35 )
Power input  (min-max)  kW 1.32 (0.79 ~2.11 ) 2.20 ( 1.21 ~ 2.86 )      3.25 ( 1.76 ~ 4.16 )
EER W/W 2.80 (2.02 ~ 3.36 ) 2.80 ( 2.00 ~ 3.42 )      2.85 ( 2.05 ~ 3.42 )
Erp
SCOP( TWW for 35ºC class ) N/A 4.47 4.49 4.59
Energy label( TWW at 35ºC) N/A A+++ A+++ A+++
SCOP( TWW for 55ºC class ) N/A 3.59 3.58 3.67
Energy label( TWW at 55ºC) N/A A++ A++ A++
 
Power supply V/Ph/Hz 220~240/ 1N/ 50 220~240/ 1N/ 50 220~240/ 1N/ 50
Compressor type N/A DC inverter DC inverter DC inverter
Fan motor N/A DC DC DC
Fan motor quantity Pc 1 1 2
Refrigerant N/A R290 ( 700g ) R290 ( 1100g ) R290 (1200g)
CO2 equivalent T 0.0021 0.0033 0.0036
Refrigerant regulation N/A  Electronic expansion valve 
Defrosting N/A Auto-defrosting
Heat exchanger type N/A Brazed plate heat exchanger 
Water connection Inch 1 1 1
Norminal water flow  m3/h 1.4 1.8 2.7
Operating outdoor temperature  ºC -25 ~ 43 -25 ~ 43 -25 ~ 43
Max heating water temperature ºC 75 75 75
Min cooling water temperature  ºC 10 10 10
Sound level dB(A) 60 63 67
Degree of protection N/A IPX4 IPX4 IPX4
Net Weight Kg          80          85 99
Dimension ( L*W*H) mm 1100*460*795 1100*460*795 1115*470*1020

About our factory: 

Guangteng New Energy Co., Ltd has been committed to the development, production, marketing and after-sales service of heat pump water heaters since founded in 2003, and granted as credit business enterprise by China Government.

Our factory locates in Shunde,China, with 10000 square meters of production workshop, modern production equipments, experienced management and development teams. We carry out ISO9001 quality control system to ensure that providing top quality products and service to our customers, quality permeate into every detail of products. So far our partners throughout Europe,Australia, Africa, Middle East, South America and etc.

Factory Real Estate
Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump
Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump

Our certificate ( ISO9001, ISO14001, CE, CB, CQC, CB ): 
Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump

Container Loading:  

Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump


Sample Project: 
Low Gwp R290 Refrigerant Heating Cooling Monoblock Heat Pump

FAQ: 
Q1 How about your delivery time ?
A1 Generally, it will take 35 to 40 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.
Q2 What is your term of delivery ?
A2 EXW, FOB, LC, etc
Q3 What is your terms of packing?
A3 Generally, we pack the heat pump in  brown cartons or plywood. If you have legally registered patent, we can pack the heat pump in your branded boxes after getting your authorization letters.
Q4 What is your sample policy?
A4 We accept the sample order, but the customers have to pay the sample cost and the courier cost.
Q5 Do you test all your goods before delivery?
A5 Yes, we have 100% test before we pack the goods for delivery
Q6 How long is the guarantee time?
A6 2 years warranty on the whole unit. The spare parts must be non-humanly damaged, usually we give to customer 1% spare parts free of charge for maintenance according to order cost during the warranty period.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now