Customization: | Available |
---|---|
Energy Efficiency Grade: | One |
Heat Temperature: | 50-70°C |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
* EVI DC Inverter compressor & R410A Refrigerant |
* Evaporator : Blue colour hydrophilic aluminum fins |
* Brazed plate heat exchanger |
* "Saginomiya" electronic expansion valve and 4-way valve |
* The water pump is optional |
* LCD controller |
*Outer Casing: galvanized steel with polyester powder painting |
* Delivery time: 30~35 days |
* Payment term: T/T 30% in advance and T/T 70% before delivery |
* Warranty time: 36 months after delivery |
Model number | GT-SKR015KBDC-S10 | GT-SKR020KBDC-S10 | GT-SKR030KBDC-S10 | GT-SKR040KBDC-S10 | GT-SKR050KBDC-S10 | |
Energy lable (EN14825) | A++ | A++ | A++ | A++ | A++ |
Heating at A7/W35 | ||||||
heating capacity (min~max) | KW | 6.00 (3.00~7.00) | 10.20 (5.00~11.20) | 13.00 (6.40~15.00) | 15.20 (7.10~16.50) | 18.30 (8.70~20.30) |
power input (min~max) | KW | 1.45(0.80~1.90) | 2.45 (1.20~2.90) | 3.17 (1.62~3.90) | 3.75 (2.08~4.85) | 4.45 (2.20~5.30) |
COP | W/W | 4.14 | 4.16 | 4.10 | 4.10 | 4.11 |
Heating at A2/W35 | ||||||
heating capacity (min~max) | KW | 5.70 (2.50~6.30) | 9.70 (4.40~10.50) | 12.30 (5.30~13.30) | 14.40 (6.10~15.90) | 17.40 (7.20~19.0) |
power input (min~max) | KW | 1.53 (0.80~2.05) | 2.58 (1.41~3.45) | 3.29 (2.85~3.87) | 3.86 (1.77~4.33) | 4.64 (3.87~5.25) |
COP | W/W | 3.73 | 3.75 | 3.74 | 3.73 | 3.75 |
Heating at A-7/W35 | ||||||
heating capacity (min~max) | KW | 5.30 (2.10~5.50) | 9.24 (3.70~9.80) | 11.00 (4.35~11.43) | 12.23 (4.90~12.95) | 14.77 (5.90~15.50) |
power input (min~max) | KW | 1.75 (0.72~1.90) | 3.08 (1.41~3.45) | 3.65 (1.52~3.87) | 3.96 (1.70~4.20) | 4.90 (2.06~5.20) |
COP | W/W | 3.03 | 3.00 | 3.02 | 3.09 | 3.02 |
Cooling at A35/W7 | ||||||
Cooling capacity (min~max) | KW | 4.50 (2.00~5.00) | 9.24 (3.80~8.50) | 9.01 (4.20~11.20) | 11.00 (5.30~14.30) | 14.00 (5.70~15.20) |
power input (min~max) | KW | 1.60 (0.80~2.10) | 2.78 (1.40~3.50) | 3.21 (1.72~4.79) | 3.92 (2.15-6.08) | 4.95 (2.35~6.52) |
EER | W/W | 2.81 | 2.81 | 2.83 | 2.81 | 2.83 |
Power supply | V/Ph/Hz | 220~240/1/50 | 220~240/1/50 | 220~240/1/50 | 220~240/1/50 | 380~415/3/50 |
Compressor type | N/A | EVI DC Inverter | EVI DC Inverter | EVI DC Inverter | EVI DC Inverter | EVI DC Inverter |
Compressor quantity | pc | 1 | 1 | 1 | 1 | 1 |
Fan type | N/A | Axial | Axial | Axial | Axial | Axial |
Fan quantity | pc | 1 | 1 | 1 | 2 | 2 |
Refrigerant | N/A | R410A | R410A | R410A | R410A | R410A |
Refrigerant regulation | N/A | EEV | EEV | EEV | EEV | EEV |
Defrosting | N/A | Auto-defrosting | Auto-defrosting | Auto-defrosting | Auto-defrosting | Auto-defrosting |
Water circulation pump | N/A | SHIMGE | SHIMGE | SHIMGE | SHIMGE | SHIMGE |
Heat exchanger | N/A | Brazed plate heat exchanger | ||||
Outdoor operating temperature | ºC | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 |
Water connection | Inch | 1 | 1 | 1 | 1 | 1 |
Sound level | dB(A) | 52 | 54 | 56 | 58 | 58 |
Max water temperature | ºC | 60 | 60 | 60 | 60 | 60 |
Max DHW temperature | ºC | 55 | 55 | 55 | 55 | 55 |
Degree of protection | N/A | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 |
Net weight of outdoor unit | kg | 75 | 81 | 102 | 109 | 130 |
Net weight of indoor unit | kg | 20 | 21 | 22 | 22.5 | 23 |
Dimension of outdoor unit | mm | 1070*500*800 | 1070*500*800 | 1110*470*860 | 1110*470*1000 | 1165*470*1270 |
Dimension of indoor unit | mm | 460*230*640 | 460*230*640 | 460*230*640 | 460*230*640 | 460*230*640 |
Test condition: | ||||
1. A7/W35: outdoor air temperature 7ºC DB / 6ºC WB, water inlet/outlet temperature 30ºC / 35ºC. | ||||
2. A2/W35: outdoor air temperature 2ºC DB / 1ºC WB, water inlet/outlet temperature 30ºC / 35ºC. | ||||
3. A-7W35: outdoor air temperature -7ºC DB / -8ºC WB, water inlet/outlet temperature 30ºC / 35ºC. | ||||
4. A35/W7: outdoor air temperature 35ºC , water inlet/outlet temperature 12ºC / 7ºC. |
Q1 | How about your delivery time ? |
A1 | Generally, it will take 35 to 40 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order. |
Q2 | What is your term of delivery ? |
A2 | EXW, FOB, LC, etc |
Q3 | What is your terms of packing? |
A3 | Generally, we pack the heat pump in brown cartons or plywood. If you have legally registered patent, we can pack the heat pump in your branded boxes after getting your authorization letters. |
Q4 | What is your sample policy? |
A4 | We accept the sample order, but the customers have to pay the sample cost and the courier cost. |
Q5 | Do you test all your goods before delivery? |
A5 | Yes, we have 100% test before we pack the goods for delivery |
Q6 | How long is the guarantee time? |
A6 | 3-year warranty on the whole unit. The spare parts must be non-humanly damaged, usually we give to customer 1.5% spare parts free of charge for maintenance according to order cost during the warranty period. |